Improved Cooling in the End Region of a Strip-Wound Totally Enclosed Fan-Cooled Induction Electric Machine
Author :
Micallef, Christopher ; Pickering, Stephen J. ; Simmons, Kathy A. ; Bradley, Keith J.
Author_Institution :
Univ. of Malta, Msida
Volume :
55
Issue :
10
fYear :
2008
Firstpage :
3517
Lastpage :
3524
Abstract :
Computational fluid-dynamics modeling has been used to investigate the cooling of the end region of a two-pole strip-wound totally enclosed fan-cooled induction motor. The modeling is validated by experimental measurements. The changes in airflow and heat transfer that each configuration gives are discussed, and recommendations are made of features that can be used to achieve lower convective thermal resistance in the end region.
Keywords :
asynchronous machines; computational fluid dynamics; cooling; fans; airflow; computational fluid-dynamics modeling; cooling; heat transfer; strip-wound-totally enclosed fan-cooled induction electric machine; Associate members; Computational fluid dynamics; Cooling; Electric machines; Heat transfer; Induction motors; Machine windings; Resistance heating; Temperature; Thermal resistance; Cooling; electric machines; end winding; totally enclosed fan cooled (TEFC);