DocumentCode :
877228
Title :
A circuit for lead resistance compensation and complex balancing of the strain-gauge bridge
Author :
Vyroubal, Darko
Author_Institution :
Jugoturbina Inst., Karlovac, Croatia
Volume :
42
Issue :
1
fYear :
1993
fDate :
2/1/1993 12:00:00 AM
Firstpage :
44
Lastpage :
48
Abstract :
In some specific applications, the strain-gauge bridge branches are separated and remote. Lead resistances between bridge branches and the measuring instrument introduce significant measurement error. The well-known error compensating circuits do not suit all applications, or they cannot be added to the already existing instrumentation without modification of its internal circuits. A circuit for lead resistance compensation and complex balancing of the 1/4 and 1/2, AC or DC excited bridges is described. It is possible to add this circuit in front of the instrumentation already in use with no modification of the instrumentation itself
Keywords :
bridge instruments; error compensation; measurement errors; strain gauges; AC; DC; complex balancing; lead resistance compensation; measurement error; strain-gauge bridge; Artificial intelligence; Bridge circuits; Cables; Electrical resistance measurement; Equivalent circuits; Feedback circuits; Instruments; Measurement errors; Mirrors; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.206678
Filename :
206678
Link To Document :
بازگشت