• DocumentCode
    878765
  • Title

    A damper for the p injection oscillations in the PS machine

  • Author

    Brouzet, E. ; Cappi, R. ; Gonzalez, J-L. ; Pirkl, W. ; Schulte, E. ; Thivent, M.

  • Author_Institution
    CERN, 1211 Geneva 23, Switzerland
  • Volume
    32
  • Issue
    5
  • fYear
    1985
  • Firstpage
    2135
  • Lastpage
    2137
  • Abstract
    After accumulation in the AA ring, at 3.5 GeV/c, the antiprotons are injected as a low intensity (109, 1010 ppb), 80 nsec singlte bunch into the PS machine, accelerated up to 26 GeV/c and then transferred to the SPS collider. Random transverse errors at injection into the PS lead to beam oscillations which increase the transverse emittances and decrease finally the luminosity in the collider. As part of the improvement program for the pp run at the end of last year a ´damper´ has been installed in the PS to counteract such oscillations. This paper describes the justifications, the technical solutions and the results of such an equipment.
  • Keywords
    Acceleration; Colliding beam devices; Damping; Data mining; Electrodes; Hardware; Information filtering; Information filters; Resonance; Shock absorbers;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4333840
  • Filename