DocumentCode :
879530
Title :
Observation of faults in convertor bridges
Author :
Fernando, C.E.
Volume :
5
Issue :
9
fYear :
1969
Firstpage :
195
Lastpage :
196
Abstract :
A method of simultaneously monitoring the seven valves in a 3-phase Graetz bridge circuit is described. The d.c. smoothing-inductor voltage is observed for this purpose. It is shown that the point of failure on the voltage wave of the malfunctioning valve can be found.
Keywords :
fault location; rectifiers;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19690148
Filename :
4210362
Link To Document :
بازگشت