DocumentCode :
880106
Title :
Calibration and testing facility for resistance welding current monitors
Author :
Destefan, Dennis E.
Author_Institution :
Precision Joining Center, EG&G Rocky Flats Inc., Golden, CO, USA
Volume :
45
Issue :
2
fYear :
1996
fDate :
4/1/1996 12:00:00 AM
Firstpage :
453
Lastpage :
456
Abstract :
The lack of uniform and traceable measurement of pulsed high currents (1-200 kA) utilized in the resistance welding process has long been a problem in the welding community. A testing facility utilizing equipment and knowledge gained in the Department of Energy programs is being made available to the American welding industry to solve these problems. Problems in making these measurements traceable to national standards and proposed solutions are presented. Test equipment and methods are described that will be used to evaluate current-sensing coils and weld-current monitors. Comparison of positional errors for various current-sensing coils is presented, including a recently developed, machinable Rogowski coil
Keywords :
calibration; coils; electric current measurement; electric sensing devices; electric welding; magnetic sensors; measurement errors; measurement standards; resistance welding; test equipment; test facilities; welding equipment; 1 to 200 kA; Faraday cage; calibration; current-sensing coils; machinable Rogowski coil; national standards; positional errors; pulsed high currents; resistance welding current monitors; testing facility; traceable measurement; Calibration; Coils; Current measurement; Electrical resistance measurement; Manufacturing; Measurement standards; NIST; Pulse measurements; Testing; Welding;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.492766
Filename :
492766
Link To Document :
بازگشت