• DocumentCode
    880236
  • Title

    Machinable Rogowski coil, design, and calibration

  • Author

    Ramboz, John D.

  • Author_Institution
    RAMTech Eng. Inc., Clermont, FL, USA
  • Volume
    45
  • Issue
    2
  • fYear
    1996
  • fDate
    4/1/1996 12:00:00 AM
  • Firstpage
    511
  • Lastpage
    515
  • Abstract
    Rogowski coils are special types of mutual inductors often used to measure high AC and transient currents. Traditional designs are reviewed. The significant sources of error associated with typical coil designs are examined. A “machinable Rogowski coil” is introduced and discussed. The reasoning behind critical design choices is discussed. The improved performance of the machinable coil is compared to that of other designs. Test and calibration methods are discussed
  • Keywords
    calibration; coils; electric current measurement; electric sensing devices; inductors; AC current measurement; calibration methods; coil design; critical design choices; current sensors; edge test; linearity; machinable Rogowski coil; mutual inductors; off-centre rotational test; pancake test; sources of error; transient current measurement; Calibration; Coils; Conductors; Current measurement; Inductance; Inductors; Instruments; Noise measurement; Shape; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.492777
  • Filename
    492777