DocumentCode :
880310
Title :
Use of a Minimum-Ellipse Criterion in the Study of Ion-Beam Extraction Systems
Author :
Keller, Roderich ; Sherman, Joseph D. ; Allison, Paul
Author_Institution :
AT-2, MS H818 Los Alamos National Laboratory, Los Alamos, NM 87544 USA
Volume :
32
Issue :
5
fYear :
1985
Firstpage :
2579
Lastpage :
2581
Abstract :
Ion-beam extraction systems may be optimized by ray-tracing codes. As a general criterion for comparing the geometry-dependent phase-space distributions, we first calculate the minimum-area ellipse that encloses all particles of any given two-dimensional phase-space distribution. Then, the relation between ellipse area and contained beam fraction is established by systematically finding and eliminating those particles that contribute most heavily to the emittance. Prescriptions for finding the minimum ellipse and beam fractions will be presented. The minimum and rms ellipses are compared for two code-calculated distributions that represent ion-beam extraction geometries.
Keywords :
Algorithm design and analysis; Differential equations; Geometry; Kinematics; Laboratories; Particle beams; Probability distribution; Ray tracing; Shape; Tail;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4333986
Filename :
4333986
Link To Document :
بازگشت