DocumentCode
880310
Title
Use of a Minimum-Ellipse Criterion in the Study of Ion-Beam Extraction Systems
Author
Keller, Roderich ; Sherman, Joseph D. ; Allison, Paul
Author_Institution
AT-2, MS H818 Los Alamos National Laboratory, Los Alamos, NM 87544 USA
Volume
32
Issue
5
fYear
1985
Firstpage
2579
Lastpage
2581
Abstract
Ion-beam extraction systems may be optimized by ray-tracing codes. As a general criterion for comparing the geometry-dependent phase-space distributions, we first calculate the minimum-area ellipse that encloses all particles of any given two-dimensional phase-space distribution. Then, the relation between ellipse area and contained beam fraction is established by systematically finding and eliminating those particles that contribute most heavily to the emittance. Prescriptions for finding the minimum ellipse and beam fractions will be presented. The minimum and rms ellipses are compared for two code-calculated distributions that represent ion-beam extraction geometries.
Keywords
Algorithm design and analysis; Differential equations; Geometry; Kinematics; Laboratories; Particle beams; Probability distribution; Ray tracing; Shape; Tail;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4333986
Filename
4333986