• DocumentCode
    880400
  • Title

    Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: a simulation study

  • Author

    Buliev, Ivan G. ; Badea, Cristian T. ; Kolitsi, Zoi ; Pallikarakis, Nicolas

  • Author_Institution
    Dept. of Med. Phys., Patras Univ., Greece
  • Volume
    7
  • Issue
    4
  • fYear
    2003
  • Firstpage
    404
  • Lastpage
    411
  • Abstract
    Computed tomography (CT) reconstruction methods assume imaging of static objects; object movement during projection data acquisition causes tomogram artifacts. The continuously moving heart, therefore, represents a complicated imaging case. The associated problems due to the heart beating can be overcome either by using very short projection acquisition times, during which the heart may be considered static, or by ECG-gated acquisition. In the latter case, however, the acquisition of a large number of projections may not be completed in a single breath hold, thus heart displacement occurs as an additional problem. This problem has been addressed by applying heart motion models in various respiratory motion compensation algorithms. Our paper focuses on cone beam computed tomography (CBCT), performed in conjunction with isocentric, fluoroscopic equipment, and continuous ECG and respiratory monitoring. Such equipment is used primarily for in-theater three-dimensional (3-D) imaging and benefits particularly from the recent developments in flat panel detector technologies. The objectives of this paper are: (i) to develop a model for the motion of the heart due to respiration during the respiratory cycle; (ii) to apply this model to the tomographic reconstruction algorithm, in order to account for heart movement due to respiration in the reconstruction; and (iii) to initially evaluate this method by means of simulation studies. Based on simulation studies, we were able to demonstrate that heart displacement due to respiration can be estimated from the same projection data, required for a CBCT reconstruction. Our paper includes semiautomatic segmentation of the heart on the X-ray projections and reconstruction of a convex 3-D-heart object that performs the same motion as the heart during respiration, and use of this information into the CBCT reconstruction algorithm. The results reveal significant image quality improvements in cardiac image reconstruction.
  • Keywords
    cardiology; computerised tomography; diagnostic radiography; image reconstruction; interpolation; medical image processing; motion estimation; phantoms; X-ray projections; cardiac image reconstruction; cone beam computed tomography imaging; harmonic interpolation functions; heart displacement; heart respiratory motion estimation; image quality improvements; isocentric fluoroscopy; phantom; respiratory monitoring; semiautomatic segmentation; simulation studies; three-dimensional imaging; tomogram artifacts; Computational modeling; Computed tomography; Data acquisition; Electrocardiography; Heart; Image reconstruction; Monitoring; Motion compensation; Motion estimation; Reconstruction algorithms; Algorithms; Artifacts; Electrocardiography; Feasibility Studies; Heart; Humans; Imaging, Three-Dimensional; Models, Biological; Movement; Phantoms, Imaging; Radiographic Image Enhancement; Reproducibility of Results; Respiratory Mechanics; Sensitivity and Specificity; Tomography, X-Ray Computed;
  • fLanguage
    English