DocumentCode :
880623
Title :
Front-end electronics for the CDF-II time-of-flight system
Author :
Chen, C. ; Jones, M. ; Kononenko, W. ; Kroll, J. ; Mayers, G.M. ; Newcomer, F.M. ; Oldeman, R.G.C. ; Usynin, D. ; Van Berg, R.
Author_Institution :
Dept. of Phys. & Astron., Univ. of Pennsylvania, Philadelphia, PA, USA
Volume :
50
Issue :
6
fYear :
2003
Firstpage :
2486
Lastpage :
2490
Abstract :
A time-of-flight (TOF) detector has been added to the CDF-II experiment to provide charged kaon identification primarily for neutral B meson flavor determination. The TOF front-end electronics system has 432 channels and is designed to run at the 7.58 MHz clock rate in CDF. The electronics contributes less than 10 ps to the TOF timing resolution of 120 ps, which is dominated by photon statistics. This paper describes the design and implementation of the electronics as well as the in situ performance.
Keywords :
B mesons; flavour model; meson detection; nuclear electronics; photomultipliers; scintillation counters; time of flight spectrometers; 7.58 MHz; CDF-II time-of-flight system; TOF detector; TOF front-end electronics system; TOF timing resolution; charged kaon identification; electronics design; in situ performance; neutral B meson flavor determination; photomultiplier; photon statistics; scintillator; Anodes; Clocks; Detectors; Mesons; Photoelectricity; Preamplifiers; Signal processing; Statistics; Timing; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2003.820632
Filename :
1263932
Link To Document :
بازگشت