DocumentCode
880624
Title
Design formulas for active RC filters using operational-amplifier biquad
Author
Tow, J.
Volume
5
Issue
15
fYear
1969
Firstpage
339
Lastpage
341
Abstract
Complete design formulas for realising any biquadratic voltage transfer function are given. The configuration uses ten or fewer resistors, two capacitors and four single-ended operational amplifiers. The realisation achieves extremely low sensitivity and can readily be used in realising stable high Q factor active filters up to 100kHz.
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19690258
Filename
4210476
Link To Document