• DocumentCode
    880721
  • Title

    Magamp postregulators for symmetrical topologies with emphasis on half-bridge configuration

  • Author

    Jamerson, Cliff ; Chen, Dan Y.

  • Author_Institution
    NCR Corp., Lake Mary, FL, USA
  • Volume
    8
  • Issue
    1
  • fYear
    1993
  • fDate
    1/1/1993 12:00:00 AM
  • Firstpage
    26
  • Lastpage
    29
  • Abstract
    The authors point out the major differences between symmetrical topology magamps and the forward converter magamp. In a forward converter, a small portion of the magnetizing current of the power transformer is diverted to the secondary for reset of the magamp´s saturable reactor. In symmetrical topologies, the transformer´s magnetizing current is not used for reset of the saturable reactor(s). The magnetizing current shifts to the secondary where it causes a series of problems. The authors examine these problems, identify solutions, and explain why a half-bridge magamp supply is inherently less versatile than is the forward converter
  • Keywords
    bridge circuits; magnetic amplifiers; power convertors; power transformers; voltage regulators; forward converter magamp; half-bridge power convertors; magnetic amplifiers; magnetizing current; postregulators; power transformer; saturable reactor; symmetrical topology magamps; voltage regulators; Circuits; Inductors; Lakes; Power systems; Power transformers; Pulse transformers; Switches; Topology; Transformer cores; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/63.208496
  • Filename
    208496