Abstract
The authors point out the major differences between symmetrical topology magamps and the forward converter magamp. In a forward converter, a small portion of the magnetizing current of the power transformer is diverted to the secondary for reset of the magamp´s saturable reactor. In symmetrical topologies, the transformer´s magnetizing current is not used for reset of the saturable reactor(s). The magnetizing current shifts to the secondary where it causes a series of problems. The authors examine these problems, identify solutions, and explain why a half-bridge magamp supply is inherently less versatile than is the forward converter
Keywords
bridge circuits; magnetic amplifiers; power convertors; power transformers; voltage regulators; forward converter magamp; half-bridge power convertors; magnetic amplifiers; magnetizing current; postregulators; power transformer; saturable reactor; symmetrical topology magamps; voltage regulators; Circuits; Inductors; Lakes; Power systems; Power transformers; Pulse transformers; Switches; Topology; Transformer cores; Voltage control;