DocumentCode :
883419
Title :
Improvement of the High Voltage Properties of the Fermilab Electrostatic Septa
Author :
Trbojevic, D. ; Crawford, C. ; Childress, S. ; Tinsley, D.
Author_Institution :
Fermi National Accelerator Laboratory P.O. Box 500 Batavia, Illinois 60510
Volume :
32
Issue :
5
fYear :
1985
Firstpage :
3074
Lastpage :
3076
Abstract :
In the Fermilab Tevatron Switchyard proton beam splits are initiated by a wire array electrostatic septum. At 1 TeV energy, and with fields limited to 50 kV/cm, and electrostatic septum more than 20 meters in length is required to produce the required angular separation between the beams for the Proton and Neutrino/Meson lines. New techniques have been investigated that will allow reliable operation at fields above 75 kV/cm with resultant beam line economy. Changes in construction and conditioning procedures have been studied using a short sample of an electrostatic septum.
Keywords :
Anodes; Cathodes; Electrodes; Electrostatics; Particle beams; Sparks; Surface cleaning; Testing; Voltage; Wires;