DocumentCode
885339
Title
SLC ARC transport system-AG-magnet measurement and performance
Author
Weng, W.T. ; Anderson, M. ; Byers, R. ; Cobb, J. ; Fischer, G. ; Hamilton, V.
Author_Institution
Stanford Linear Accelerator Center Stanford University, Stanford, California, 94305
Volume
32
Issue
5
fYear
1985
Firstpage
3660
Lastpage
3662
Abstract
This paper describes the design, construction, and operation of devices used to rapidly measure the mechanical and magnetic properties of some 950 Alternate gradient magnets1 used in the arc system of the Stanford Linear Collider. The problems of dealing with the measurement of the transverse dimensions to within minute (0.0001 in) resolution of objects that are 8 ft long are discussed. Early results from the production runs of these magnets are presented.
Keywords
Error correction; Extraterrestrial measurements; Iron; Magnetic cores; Magnetic field measurement; Magnetic properties; Magnetic variables measurement; Magnets; Mechanical variables measurement; Saturation magnetization;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4334460
Filename
4334460