• DocumentCode
    885601
  • Title

    Sextupole Correction Coils for SSC Model Dipoles

  • Author

    Rechen, J.B. ; Gilbert, W.S. ; Hassenzahl, W.V.

  • Author_Institution
    Lawrence Berkeley Laboratory University of California Berkeley, California 94720
  • Volume
    32
  • Issue
    5
  • fYear
    1985
  • Firstpage
    3731
  • Lastpage
    3733
  • Abstract
    Local correction of the sextupole error field is proposed for the dipoles of the SSC. This requirement is imposed on the design by the high field quality required both during injection at low fields and during colliding beam operation at high fields. Error fields in the main dipole windings due to superconductor magnetization and conductor misplacements add unwanted sextupole and decapole magnetic field terms. To correct the sextupole error field we have constructed sextupole coils made of a single layer of superconducting wire and have mounted them with high precision on the stainless steel bore tube. These correction coils have been operated with 1 meter long SSC model dipoles in both the self-powered and externally-powered modes. The sextupole field in the bore has been reduced by as much as a factor of 50. The level of correction depends strongly on the angular alignment of the correction coil with respect to the sextupole error field it is to correct. Results of tests, performance of the correction coils and alignment requirements for the system are presented.
  • Keywords
    Boring; Conductors; Error correction; Magnetic fields; Magnetization; Steel; Superconducting coils; Superconducting epitaxial layers; Superconducting filaments and wires; System testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4334484
  • Filename
    4334484