• DocumentCode
    886465
  • Title

    Comparison of Onetran Calculations with Cobalt-60 Dose Profile Data to Determine the Photon Spectrum

  • Author

    Woolf, S. ; Garth, J.C.

  • Author_Institution
    ARCON Corporation 260 Bear Hill Road Waltham MA 02154
  • Volume
    33
  • Issue
    6
  • fYear
    1986
  • Firstpage
    1252
  • Lastpage
    1257
  • Abstract
    The ONETRAN code was used to compute dose profiles near gold/aluminum interfaces for photon energies from 100 to 1250 keV. Weighted by a four component photon spectrum obtained from a least-squares fit to measured dose distribution data, the calculated profiles agree closely with Cobalt-60 ionization chamber data.
  • Keywords
    Aluminum; Computer interfaces; Electromagnetic scattering; Electrons; Gold; Ionization chambers; Monte Carlo methods; Particle scattering; Solid state circuits; X-ray scattering;