DocumentCode :
886537
Title :
Conversion of Depth-Dose Distributions from Slab to Spherical Geometries for Space-Shielding Applications
Author :
Seltzer, Stephen M.
Author_Institution :
National Bureau of Standards, Gaithersburg, MD 20899
Volume :
33
Issue :
6
fYear :
1986
Firstpage :
1292
Lastpage :
1297
Abstract :
An approximate procedure has been developed to transform depth-dose distributions in simple slab targets so as to obtain the spatial distribution of dose in spherical target configurations for space-shielding applications. Emphasis is placed on the determination of electron and bremnsstrahlung dose, which would otherwise require more costly three-dimensional Monte Carlo calculations. For the electron-bremsstrahlung problems tested, results from the procedure require only a fraction of the computer time and are found to agree to within 10-20% as compared to direct, three-dimensional Monte Carlo calculations.
Keywords :
Application software; Electronic components; Electrons; Geometry; Monte Carlo methods; Personnel; Protons; Slabs; Space vehicles; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1986.4334595