• DocumentCode
    886545
  • Title

    Time Projection Compton Spectrometer (TPCS)

  • Author

    Baldwin, George T. ; Lee, James R.

  • Volume
    33
  • Issue
    6
  • fYear
    1986
  • Firstpage
    1298
  • Lastpage
    1304
  • Abstract
    We propose a new technique for measuring the time-integrated energy spectrum of X rays emitted by high-intensity, medium-voltage flash x-ray sources. The method sorts Compton electrons by drift velocity time-of-flight in a non-uniform magnetic field. We explain a conceptual spectrometer design, show how we have modeled it using Monte Carlo methods, and discuss how one would unfold x-ray spectrum information from electron time-of-flight data. The technique appears promising, especially for short-pulse x-ray sources.
  • Keywords
    Detectors; Electron tubes; Energy measurement; Magnetic field measurement; Magnetic fields; Medium voltage; Pulse measurements; Radiation effects; Spectroscopy; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4334596
  • Filename