DocumentCode :
886545
Title :
Time Projection Compton Spectrometer (TPCS)
Author :
Baldwin, George T. ; Lee, James R.
Volume :
33
Issue :
6
fYear :
1986
Firstpage :
1298
Lastpage :
1304
Abstract :
We propose a new technique for measuring the time-integrated energy spectrum of X rays emitted by high-intensity, medium-voltage flash x-ray sources. The method sorts Compton electrons by drift velocity time-of-flight in a non-uniform magnetic field. We explain a conceptual spectrometer design, show how we have modeled it using Monte Carlo methods, and discuss how one would unfold x-ray spectrum information from electron time-of-flight data. The technique appears promising, especially for short-pulse x-ray sources.
Keywords :
Detectors; Electron tubes; Energy measurement; Magnetic field measurement; Magnetic fields; Medium voltage; Pulse measurements; Radiation effects; Spectroscopy; Wire;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1986.4334596
Filename :
4334596
Link To Document :
بازگشت