    High repetition rate PEA system for in-situ space charge measurement during breakdown tests

  • Author

    Fukuma, M. ; Maeno, T. ; Fukunaga, K. ; Nagao, M.

  • Author_Institution
    Dept. of Electr. Eng., Matsue Coll. of Technol., Japan
  • Volume
    11
  • Issue
    1
  • fYear
    2004
  • Firstpage
    155
  • Lastpage
    159
  • Abstract
    In order to investigate transient space charge phenomena, it is essential that the space charge profile be observed at a high repetition rate. We have developed a new space charge measurement system using the pulsed electroacoustic (PEA) method, which can measure the space charge profiles every 10 μs. It employs the most recent digitising oscilloscope model and a semiconductor switch. The effect of prestressing on impulse breakdown voltage of a low-density polyethylene sheet was investigated by using the new system. Experimental results suggest that positive charge injection was dominant immediately before the breakdown, and charge injection during the prestressing causes distortion of the electric field near the electrode, and enhances the subsequent charge injection due to the impulse voltage.
  • Keywords
    charge injection; charge measurement; electric breakdown; pulsed electroacoustic methods; semiconductor switches; space charge; breakdown tests; charge injection; digitising oscilloscope model; electric field distortion; impulse breakdown voltage; polyethylene sheet; prestressing; pulsed electroacoustic method; semiconductor switch; space charge measurement; Breakdown voltage; Charge measurement; Current measurement; Electric breakdown; Oscilloscopes; Pulse measurements; Pulsed electroacoustic methods; Space charge; Switches; System testing;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2004.1266330
  • Filename
    1266330