DocumentCode :
889768
Title :
High repetition rate PEA system for in-situ space charge measurement during breakdown tests
Author :
Fukuma, M. ; Maeno, T. ; Fukunaga, K. ; Nagao, M.
Author_Institution :
Dept. of Electr. Eng., Matsue Coll. of Technol., Japan
Volume :
11
Issue :
1
fYear :
2004
Firstpage :
155
Lastpage :
159
Abstract :
In order to investigate transient space charge phenomena, it is essential that the space charge profile be observed at a high repetition rate. We have developed a new space charge measurement system using the pulsed electroacoustic (PEA) method, which can measure the space charge profiles every 10 μs. It employs the most recent digitising oscilloscope model and a semiconductor switch. The effect of prestressing on impulse breakdown voltage of a low-density polyethylene sheet was investigated by using the new system. Experimental results suggest that positive charge injection was dominant immediately before the breakdown, and charge injection during the prestressing causes distortion of the electric field near the electrode, and enhances the subsequent charge injection due to the impulse voltage.
Keywords :
charge injection; charge measurement; electric breakdown; pulsed electroacoustic methods; semiconductor switches; space charge; breakdown tests; charge injection; digitising oscilloscope model; electric field distortion; impulse breakdown voltage; polyethylene sheet; prestressing; pulsed electroacoustic method; semiconductor switch; space charge measurement; Breakdown voltage; Charge measurement; Current measurement; Electric breakdown; Oscilloscopes; Pulse measurements; Pulsed electroacoustic methods; Space charge; Switches; System testing;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2004.1266330
Filename :
1266330
Link To Document :
بازگشت