Abstract
A new simple balanced circuitry using four printed circuit board trace capacitors effectively detects the cold-cathode fluorescent lamp current and the transformer voltage of the inverter without grounding either side of the lamp. The inverter employing this circuit is free from the problems caused by grounding one side of the lamp, and it provides a stable and wide dimming control as well as an open-lamp voltage regulation with a better efficacy.
Keywords
cold-cathode tubes; fluorescent lamps; lighting control; resonant invertors; transformers; voltage control; cold-cathode fluorescent lamp current; cold-cathode tube; current sensing; dimming control; open-lamp voltage regulation; printed circuit board; resonant inverter; trace capacitor; transformer voltage; voltage sensing; Capacitors; Electronic ballasts; Fluorescent lamps; Grounding; Parasitic capacitance; Printed circuits; Resistors; Resonant inverters; Voltage control; Voltage measurement; Cold-cathode tube; current sensing; printed circuit board (PCB) capacitors; resonant inverters; voltage sensing;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2006.870883
Filename
1614153
Link To Document