Abstract
The paper deals with an optimized unified power-quality conditioner (UPQC), which aims at the integration of series active and shunt active power filters with minimum volt-ampere (VA) loading of the UPQC. The series active filter is a dynamic voltage restorer (DVR), which regulates the voltage at the load end with minimum VA loading of the overall UPQC by injecting the voltage at an optimum angle. The proposed scheme is validated by an experimental prototype in the laboratory. Selected experimental results are reported along with analytical findings, which show the effectiveness of the proposed UPQC
Keywords
active filters; power harmonic filters; power supply quality; dynamic voltage restorer; series active filters; shunt active power filters; single phase unified power quality conditioner; volt-ampere loading; Active filters; Automatic voltage control; Electrical equipment industry; Power harmonic filters; Power quality; Power system harmonics; Programmable control; Pulse width modulation inverters; Reactive power; Voltage fluctuations; Optimum angle voltage injection; unified power-quality conditioner (UPQC); volt-ampere (VA) optimization; voltage sag;