DocumentCode
894710
Title
The use of a circulator in device noise factor measurements
Author
Bechtel, G.
Volume
56
Issue
1
fYear
1968
Firstpage
86
Lastpage
86
Abstract
It is shown that the use of a circulator between the device under test and the preamplifier removes the necessity for matching and that the noise factor of the device can be obtained from simple measurements of insertion gain S21 , as well as the overall noise factor if the noise factor of the circulator-preamplifier combination from a matched noise generator is known.
Keywords
Circuit noise; Controllability; Gain measurement; Impedance measurement; Noise generators; Noise measurement; Power measurement; Preamplifiers; Semiconductor device noise; Testing;