• DocumentCode
    896826
  • Title

    Comparisons of Waveguide Losses Calibrated by the DC Potentiometer, AC Ratio Transformer, and Reflectometer Techniques (Correspondence)

  • Author

    Otoshi, T.Y. ; Stelzried, C.T. ; Yates, B.C. ; Beatty, R.W.

  • Volume
    18
  • Issue
    7
  • fYear
    1970
  • fDate
    7/1/1970 12:00:00 AM
  • Firstpage
    406
  • Lastpage
    409
  • Abstract
    Comparisons are made of the losses of two precision waveguide sections that were calibrated by three independent attenuation measurement methods. The loss measurement systems involved were the 1) dual-channel system which uses thermistors and a dc potentiometer test set, 2) dual-channel system which uses barretters and an ac ratio transformer test set, and 3) Nationaf Bureau of Standards reflectometer system which utilizes a quarter-wave short circuit and an IF attenuation standard. Loss values of about 0.05 dB, as calibrated by the three independent methods, typically agreed to within 0.0006 dB. It is believed that the results of these calibrations are representative of the best that can be achieved with current state-of-the-art techniques and available instrumentation for low-loss waveguide measurements.
  • Keywords
    Attenuation measurement; Calibration; Circuit testing; Current measurement; Instruments; Loss measurement; Measurement standards; Potentiometers; System testing; Thermistors;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1970.1127252
  • Filename
    1127252