DocumentCode
896826
Title
Comparisons of Waveguide Losses Calibrated by the DC Potentiometer, AC Ratio Transformer, and Reflectometer Techniques (Correspondence)
Author
Otoshi, T.Y. ; Stelzried, C.T. ; Yates, B.C. ; Beatty, R.W.
Volume
18
Issue
7
fYear
1970
fDate
7/1/1970 12:00:00 AM
Firstpage
406
Lastpage
409
Abstract
Comparisons are made of the losses of two precision waveguide sections that were calibrated by three independent attenuation measurement methods. The loss measurement systems involved were the 1) dual-channel system which uses thermistors and a dc potentiometer test set, 2) dual-channel system which uses barretters and an ac ratio transformer test set, and 3) Nationaf Bureau of Standards reflectometer system which utilizes a quarter-wave short circuit and an IF attenuation standard. Loss values of about 0.05 dB, as calibrated by the three independent methods, typically agreed to within 0.0006 dB. It is believed that the results of these calibrations are representative of the best that can be achieved with current state-of-the-art techniques and available instrumentation for low-loss waveguide measurements.
Keywords
Attenuation measurement; Calibration; Circuit testing; Current measurement; Instruments; Loss measurement; Measurement standards; Potentiometers; System testing; Thermistors;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/TMTT.1970.1127252
Filename
1127252
Link To Document