• DocumentCode
    896886
  • Title

    Development of double sided linear pulse motor

  • Author

    Karita, M. ; Nakagawa, H. ; Maeda, M. ; Yamada, H. ; Kawakatsu, K.

  • Author_Institution
    Shinko Electr. Co. Ltd., Honshu, Japan
  • Volume
    25
  • Issue
    5
  • fYear
    1989
  • fDate
    9/1/1989 12:00:00 AM
  • Firstpage
    3257
  • Lastpage
    3259
  • Abstract
    Several novel design processes have been employed to develop two types of small linear pulse motors (LPM) with high thrust and high reliability. These LPMs are small enough for use in an implantable artificial heart. High thrust force is secured by means of a double-sided structure. A laminated core of cobalt steel plates and a rare earth magnet have been employed as the magnetic materials. One LPM has a two-phase, eight pole, four-coil construction and has been developed with the principal aim of miniaturization. The other has a two-phase, twelve-pole, two-coil construction and has been developed chiefly for ease of manufacture. Both types of LPM can have two to five times better input watt ratio, mass ratio, and volumetric ratio in relation to generated thrust than the conventional LPM
  • Keywords
    linear motors; small electric machines; Co steel plates; double-sided structure; eight pole; four-coil construction; high reliability; high thrust; implantable artificial heart; laminated core; linear pulse motor; magnetic materials; rare earth magnet; twelve-pole; two-coil construction; two-phase; Artificial heart; Brushless DC motors; Brushless motors; DC motors; Humans; Hydraulic actuators; Magnetic cores; Magnetic flux; Magnetic levitation; Magnetic materials;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.42270
  • Filename
    42270