• DocumentCode
    897477
  • Title

    Proportional Tube Electromagnetic Calorimeter with Conductive Plastic Tubes

  • Author

    Atac, M. ; Yamada, R. ; Takasaki, F. ; Mishina, M. ; Ogawa, Koichi ; Hayashide, Y. ; Kim, S. ; Kondo, K. ; Miyashita, S. ; Miyata, H. ; Sato, F. ; Yasu, Y. ; Yoshino, M.

  • Author_Institution
    Fermi National Accelerator Laboratory, Batavia, IL 60510
  • Volume
    29
  • Issue
    1
  • fYear
    1982
  • Firstpage
    368
  • Lastpage
    372
  • Abstract
    A prototype electromagnetic calorimeter of lead-proportional tube layers has been built and tested at high energy beam at Fermilab. The proportional tubes were made of extruded conductive plastic and 50 um tungsten wire, and the signals were picked up by pads and strips stretched on the outside of the tubes. The basic characteristics of the tube and the detailed results from the test by 10 to 46 GeV electron and 40 GeV pion beams are prsented.
  • Keywords
    Conductivity; Electron beams; Electron tubes; Laboratories; Pattern recognition; Plastics; Prototypes; Shape; Testing; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1982.4335867
  • Filename
    4335867