• DocumentCode
    897879
  • Title

    Some results from the measurement of the noise parameters of an electron beam using a sealed-off tube

  • Author

    Ninomiya, K. ; Okoshi, Tadashi

  • Volume
    56
  • Issue
    6
  • fYear
    1968
  • fDate
    6/1/1968 12:00:00 AM
  • Firstpage
    1106
  • Lastpage
    1107
  • Abstract
    Results of the measurement of the noise parameters of an electron beam using a sealed-off tube are presented. The data suggest that the cathode coating resistance plays an important role in determining the noise parameters S and Π.
  • Keywords
    Calibration; Cathodes; Coatings; Electron beams; Electron tubes; Magnetic field measurement; Noise measurement; Plasma measurements; Voltage; Wavelength measurement;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEEE
  • Publisher
    ieee
  • ISSN
    0018-9219
  • Type

    jour

  • DOI
    10.1109/PROC.1968.6476
  • Filename
    1448406