Title :
Automatic stepped-frequency six-port reflectometer for WG22
Author :
Hill, L.D. ; Griffin, E.J.
Author_Institution :
Royal Signals and Radar Establishment, Malvern, UK
fDate :
4/1/1985 12:00:00 AM
Abstract :
A millimetre wave six-port reflectometer for the measurement of complex voltage reflection coefficient is described. The system is assembled from commercially available components and operates automatically from 26.5 to 40 GHz using a nominal 5 mW source. The paper also describes the means adopted to produce this broadband performance and the calibration method employed.
Keywords :
calibration; computerised instrumentation; microwave reflectometry; 26.5 to 40 GHz; 5 mW source; MM wave; WG22; automatic stepped-frequency six-port reflectometer; broadband performance; calibration method; complex voltage reflection coefficient; millimetre wave;
Journal_Title :
Microwaves, Antennas and Propagation, IEE Proceedings H
DOI :
10.1049/ip-h-2.1985.0016