• DocumentCode
    898141
  • Title

    Experimental Measurements of Neutron and Gamma-Ray Sensitivities of Flux Detectors Having a Mixed Response

  • Author

    Allan, C.J.

  • Author_Institution
    Atomic Energy of Canada Limited Chalk River Nuclear Laboratories, Chalk River, Ontario, Canada
  • Volume
    29
  • Issue
    1
  • fYear
    1982
  • Firstpage
    660
  • Lastpage
    664
  • Abstract
    Methods have been developed for determining the separate neutron and ¿-ray sensitivities of mixed-response self-powered flux detectors and other devices that have a significant response to both reactor ¿-rays and reactor neutrons.
  • Keywords
    Atomic measurements; Bismuth; Delay; Gamma ray detection; Gamma ray detectors; Inductors; Neutrons; Radiation detectors; Rivers; Safety;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1982.4335931
  • Filename
    4335931