• DocumentCode
    898435
  • Title

    Area Radiation Monitor at the Intense Pulsed Neutron Source

  • Author

    Eichholz, J.J. ; Lynch, F.J. ; Mundis, R.L. ; Howe, M.L. ; Dolecek, E.H.

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois 60439
  • Volume
    29
  • Issue
    1
  • fYear
    1982
  • Firstpage
    803
  • Lastpage
    807
  • Abstract
    A tissue-equivalent ionization chamber with associated circuitry has been developed for area radiation monitoring in the Intense Pulsed Neutron Source (IPNS) facility at Argonne National Laboratory. The conventional chamber configuration was modified in order to increase the electric field and effective volume thereby achieving higher sensitivity and linearity. Ihe instrument provides local and remote radiation level indications and a high level alarm. Twenty-four of these instruments were fabricated for use at various locations in the experimental area of the IPNS-1 facility.
  • Keywords
    Electrodes; Hydrogen; Instruments; Ionization chambers; Laboratories; Linearity; Neutrons; Protons; Radiation monitoring; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1982.4335963
  • Filename
    4335963