• DocumentCode
    899617
  • Title

    Comparison of Doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability

  • Author

    Jezewski, J. ; Wrobel, J. ; Horoba, K.

  • Author_Institution
    Dept. of Biomed. Informatics, Inst. of Med. Technol. & Equip., Zabrze
  • Volume
    53
  • Issue
    5
  • fYear
    2006
  • fDate
    5/1/2006 12:00:00 AM
  • Firstpage
    855
  • Lastpage
    864
  • Abstract
    A method for comparison of two acquisition techniques that are applied in clinical practice to provide information on fetal condition is presented. The aim of this work was to evaluate the commonly used Doppler ultrasound technique for monitoring of mechanical activity of fetal heart. Accuracy of beat-to-beat interval determination together with its influence on indices describing the fetal heart rate (FHR) variability calculated automatically using computer-aided fetal monitoring system were examined. We considered the direct fetal electrocardiography as a reference technique because it ensures the highest possible accuracy of heart interval measurement, and additionally all the definitions of popular time domain parameters quantifying FHR variability formerly have been created using the fetal electrocardiogram. We evaluated the reliability of various so called short-term and long-term variability indices, when they are calculated automatically using the signal obtained via the Doppler US from a fetal monitor. The results proved that evaluation of the acquisition technique influence on fetal well-being assessment cannot be accomplished basing on direct measurements of heartbeats only. The more relevant is the estimation of accuracy of the variability indices, since analysis of their changes can significantly increase predictability of fetal distress
  • Keywords
    biomedical ultrasonics; electrocardiography; medical signal detection; medical signal processing; obstetrics; patient monitoring; Doppler ultrasound technique; beat-to-beat interval determination; computer-aided fetal monitoring system; direct electrocardiography acquisition technique; fetal distress; fetal heart mechanical activity; fetal heart rate variability; long-term variability indices; short-term variability indices; Biomedical measurements; Computerized monitoring; Electrocardiography; Envelope detectors; Fetal heart; Fetal heart rate; Heart rate measurement; Patient monitoring; Ultrasonic imaging; Ultrasonic variables measurement; Doppler ultrasound; fetal electrocardiogram; fetal heart rate; fetal monitoring; Algorithms; Echocardiography, Doppler; Electrocardiography; Fetal Distress; Fetal Monitoring; Heart Rate, Fetal; Humans; Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography, Prenatal;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2005.863945
  • Filename
    1621137