• DocumentCode
    900882
  • Title

    Technical memorandum estmating the residual error from calibrating a reflectometer with a sliding termination

  • Author

    Griffin, E.J. ; Hodgetts, T.E.

  • Author_Institution
    Royal Signals & Radar Establishment, Malvern, UK
  • Volume
    134
  • Issue
    6
  • fYear
    1987
  • fDate
    12/1/1987 12:00:00 AM
  • Firstpage
    560
  • Lastpage
    562
  • Abstract
    A sliding termination is often used to approximate to ¿¿ = 0 when calibrating a reflect-ometer with equivalent generator mismatch ¿¿G. The paper shows that a residual error of ¿¿G*|¿¿T|2 results (where |¿¿T| is the amplitude of reflection from the variable phase load and * denotes complex conjugate) and compares this error with the precision of available calibration standards.
  • Keywords
    calibration; measurement errors; measurement standards; microwave reflectometry; calibration; calibration standards; complex conjugate; equivalent generator mismatch; reflection amplitude; reflectometer; residual error; sliding termination; variable phase load;
  • fLanguage
    English
  • Journal_Title
    Microwaves, Antennas and Propagation, IEE Proceedings H
  • Publisher
    iet
  • ISSN
    0950-107X
  • Type

    jour

  • DOI
    10.1049/ip-h-2.1987.0111
  • Filename