DocumentCode :
901064
Title :
Errors in S11 Measurements Due to the Residual Standing-Wave Ratio of the Measuring Equipment
Author :
Garver, Robert V. ; Bergfried, Dietrich E. ; Raff, Samuel J. ; Weinschel, Bruno O.
Volume :
20
Issue :
1
fYear :
1972
fDate :
1/1/1972 12:00:00 AM
Firstpage :
61
Lastpage :
69
Abstract :
Errors in measurement of S11 due to the residual SWR of the slotted line or directional coupler are calculated using admittance considerations. This more complete treatment produces, for some practical conditions, major differences from prior references for phase errors.
Keywords :
Admittance; Computer errors; Directional couplers; Equations; Error correction; Impedance; Manufacturing processes; Mathematics; Microwave devices; Reflection;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/TMTT.1972.1127681
Filename :
1127681
Link To Document :
بازگشت