• DocumentCode
    901980
  • Title

    Electric Breakdown of Earth in Coaxial Geometry

  • Author

    van Lint, V.A.J. ; Erler, J.W.

  • Author_Institution
    Mission Research Corporation San Diego, CA 92123
  • Volume
    29
  • Issue
    6
  • fYear
    1982
  • Firstpage
    1891
  • Lastpage
    1896
  • Abstract
    The resistance of earth under high electric stress was determined in 90° sector and 360° coaxial geometry by measuring the voltage at various radii. Streamers were observed to propagate outward from the center conductor after delays ranging up to 1 ms. Stable streamer configurations without arc-over between electrodes apparently exhibited relatively few (¿ 6) longer streamers in 360° × 1 m long geometry.
  • Keywords
    Coaxial components; Conductors; Earth; Electric breakdown; Electric resistance; Electric variables measurement; Electrical resistance measurement; Geometry; Stress measurement; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1982.4336466
  • Filename
    4336466