DocumentCode :
902198
Title :
Electrical operating and stability region for MHD generator/inverter link
Author :
Trung, D.T. ; Messerle, H.K.
Author_Institution :
University of Sydney, School of Electrical Engineering, Sydney, Australia
Volume :
128
Issue :
1
fYear :
1981
fDate :
1/1/1981 12:00:00 AM
Firstpage :
28
Lastpage :
32
Abstract :
This paper examines the necessary conditions for a successful power conversion and transfer between one pair of electrodes of an MHD generator and a three-phase six-pulse line-commutated inverter. The electrodes are assumed to have a linear voltage/current characteristic. The inverter is supplied from an infinite AC busbar. The conditions are found to consist of three sets of constraints which: relate the electrical parameters of the generator and the inverter; limit the ranges of the inverter thyristor firing angle; and relate the magnitude of the inverter smoothing inductance and the time constant and loop gain of the inverter control circuit
Keywords :
invertors; magnetohydrodynamic convertors; stability; MHD generator/inverter link; electrical operating regions; stability region;
fLanguage :
English
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings C
Publisher :
iet
ISSN :
0143-7046
Type :
jour
DOI :
10.1049/ip-c.1981.0005
Filename :
4643316
Link To Document :
بازگشت