Title :
The biomechanics of lumbar graded facetectomy under anterior-shear load
Author :
Teo, E.C. ; Lee, K.K. ; Qiu, T.X. ; Ng, H.W. ; Yang, K.
Author_Institution :
Sch. of Mech. & Production Eng., Nanyang Technol. Univ., Singapore
fDate :
3/1/2004 12:00:00 AM
Abstract :
In this paper, an anatomically accurate three-dimensional finite-element (FE) model of the human lumbar spine (L2-L3) was used to study the biomechanical effects of graded bilateral and unilateral facetectomies of L3 under anterior shear. The intact L2-L3 FE model was validated under compression, tension, and shear loading and the predicted responses matched well with experimental data. The gross external (translational and coupled) responses, flexibilities, and facet load were delineated for these iatrogenic changes. Results indicted that unilateral facetectomy of greater than 75% and bilateral facetectomy of 75% or more resection markedly alter the translational displacement and flexibilities of the motion segment. This study suggests that fixation or fusion to restore strength and stability of the lumbar spine may be required for surgical intervention of greater than 75% facetectomy.
Keywords :
biomechanics; bone; finite element analysis; anterior-shear load; bilateral facetectomy; biomechanics; compression; flexibilities; gross external responses; human lumbar spine; iatrogenic changes; lumbar graded facetectomy; lumbar spine stability; lumbar spine strength; motion segment; tension; three-dimensional finite-element model; translational displacement; unilateral facetectomy; Biomechanics; Finite element methods; Humans; In vitro; Ligaments; Pain; Production engineering; Spine; Stability; Surgery; Biomechanics; Cadaver; Computer Simulation; Decompression, Surgical; Elasticity; Finite Element Analysis; Humans; Joint Instability; Laminectomy; Lumbar Vertebrae; Male; Middle Aged; Models, Biological; Motion; Shear Strength; Stress, Mechanical; Treatment Outcome; Weight-Bearing;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2003.821009