• DocumentCode
    902596
  • Title

    Magneto-optic magnetic field sensor with 1.4 pT/ square root (Hz) minimum detectable field at 1 kHz

  • Author

    Day, G.W. ; Beahn, T.J. ; Manheimer, Marc

  • Volume
    29
  • Issue
    11
  • fYear
    1993
  • fDate
    5/27/1993 12:00:00 AM
  • Firstpage
    993
  • Lastpage
    994
  • Abstract
    The Letter demonstrates that the sensitivity of magneto-optic magnetic field sensors employing iron garnets can be increased by approximately two orders of magnitude by applying flux concentration. A minimum detectable field of 1.4 pT/ square root (Hz) was measured when a cylindrical gallium-substituted yttrium iron garnet crystal was combined with two conically tapered nickel-zinc ferrite cylinders.
  • Keywords
    garnets; magnetic field measurement; magnetic flux; magneto-optical devices; optical sensors; yttrium compounds; 1 kHz; YFe5O12Ga5O12; YIGGG; conically tapered NiZnFe 2O 4 cylinders; flux concentration; magneto-optic magnetic field sensors; minimum detectable field; sensitivity;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19930661
  • Filename