DocumentCode
903389
Title
Comments and further results on "A New Critical Formula and Mathematical Model of Double-Tap Interphase Reactor in a Six-Phase Tap-Changer Diode Rectifier
Author
Meng, Fangang ; Yang, Shiyan ; Yang, Wei ; Jin, Xiaozhong
Author_Institution
Sch. of Electr. Eng. & Autom., Harbin Inst. of Technol., Harbin, China
Volume
57
Issue
3
fYear
2010
fDate
3/1/2010 12:00:00 AM
Firstpage
950
Lastpage
953
Abstract
This paper presents some comments and further results concerning the mathematical model of double-tap interphase reactor (IPR) in a six-phase tap-changer diode rectifier. On the basis of coupling circuit principle and phase-coordinate method, the proposed model, which reduces the mutual inductance coupling completely, describes the double-tap IPR by an admittance matrix containing the information about the connection way and electrical quantities. Some computer simulation and experiments are included to support the theoretical analysis of the model.
Keywords
inductance; rectifiers; admittance matrix; double-tap interphase reactor; six-phase tap-changer diode rectifier; Admittance; Computer simulation; Coupling circuits; Diodes; Inductance; Inductors; Intellectual property; Mathematical model; Mutual coupling; Rectifiers; Double-tap changer; interphase reactor (IPR); mathematical model;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2009.2023097