DocumentCode
904144
Title
Calculation of corona onset voltage for duct-type precipitators
Author
Abdel-Salam, Mazen ; Wiitanen, Dennis
Author_Institution
Dept. of Electr. Eng., King Fahd Univ. of Pet. & Miner., Dhahan, Saudi Arabia
Volume
29
Issue
2
fYear
1993
Firstpage
274
Lastpage
280
Abstract
A pure theoretical method for calculating the onset voltage of corona in duct-type electrostatic precipitators that is independent of the arrangement of discharge wires relative to the collecting plates is described. This method is based on a criterion for self-recurring single electron avalanches in a known electric field distribution in the ionization zone surrounding the discharge wire. The results computed by this method are in reasonable agreement with those measured experimentally
Keywords
corona; discharges (electric); electric fields; electrostatic precipitators; corona onset voltage; discharge wires; duct-type electrostatic precipitators; field distribution; ionization zone; self-recurring single electron avalanches; Atmospheric measurements; Corona; Electrons; Electrostatic measurements; Equations; Industry Applications Society; Ionization; Pollution measurement; Voltage; Wires;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.216532
Filename
216532