DocumentCode
904853
Title
Cryogenic System for Production Testing and Measurement of Fermilab Energy Saver Superconducting Magnets
Author
Per, Coo ; Bianchi, A.J. ; Barger, R.K. ; Johnson, F.B. ; McGuire, K.J. ; Pinyan, K.D. ; Wilson, F.R.
Author_Institution
Fermi National Accelerator Laboratory, Batavia, Illinois 60510
Volume
30
Issue
4
fYear
1983
Firstpage
3602
Lastpage
3604
Abstract
The cryogenic system of the Fermilab Magnet Test Facility has been used to provide cooling for the testting of approximately 1200 Energy Saver superconducting magnets. The system provides liquid helium, liquid nitrogen, gas purification, and vacuum support for six magnet test stands. It provides for simultaneous high current testing of two superconducting magnets and non-high current cold testing of two additional magnets. The cryogenic system has been in operation for about 32000 hours. The 1200 magnets have taken slightly more than three years to test.
Keywords
Cooling; Cryogenics; Energy measurement; Helium; Nitrogen; Production systems; Purification; Superconducting magnets; System testing; Test facilities;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4336739