DocumentCode :
905496
Title :
The Vernier Delay Unit
Author :
Pierce, W.B.
Author_Institution :
Stanford Linear Accelerator Center Stanford University Stanford, California 94305
Volume :
32
Issue :
1
fYear :
1985
Firstpage :
95
Lastpage :
99
Abstract :
This module will accept differential ECL pulses from the auxiliary rear panel or NIM level pulses from the front panel. The pulses are produced at the output with a fixed delay that is software programmable in steps of 0.1 ns over the range of 0.1 to 10.5 ns. Multiple outputs are available at the front panel. Minimum delay through the module is 9 ns.
Keywords :
Backplanes; Calibration; Damping; Delay lines; Linear accelerators; Magnets; Pulse measurements; Space vector pulse width modulation; Testing; Timing;