Title :
Radial Drift Chambers Fop CDF Forward Tracking
Author :
Atac, M. ; Handler, R. ; Pondrom, L. ; Reeder, D. ; Sheaff, M.
Author_Institution :
Fermi National Accelerator Laboratory, Batavia, IL 60439
Abstract :
Radial wire drift chambers are built for the Collider Detector of Fermilab to cover forward and backward regions between 2° and 10° cones which will provide good azimuthal position information of tracks, good multi-track, and high rate capability. Results obtained from a prototype chamber show ¿ resolution of ¿rms ¿ 130 ¿m and a charge division accuracy of 0.7 percent along the wire (¿,r) running in the saturated avalanche mode.
Keywords :
Aluminum; Breakdown voltage; Cathodes; Detectors; Electrons; Laboratories; Prototypes; Sheet materials; Testing; Wires;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :