DocumentCode :
906704
Title :
100 MHz 10-Bit Image Chamber Analyzers
Author :
Farr, W. ; Levit, L.B. ; Uhmeyer, U.A.
Author_Institution :
LeCroy Research Systems Corporation 700 S. Main St., Spring Valley, N.Y. 10977
Volume :
32
Issue :
1
fYear :
1985
Firstpage :
636
Lastpage :
639
Abstract :
A high-performance, custom monolithic charge-coupled device (CCD) is used as a key element in two Image Chamber Analyzers (ICA). The CAMAC ICA can operate either as a 4-channel unit with a maximum number of 320 sampling points per channel and a variable sampling rate of up to 50 MHz, or as a 2-channel unit with 640 samples and up to 100 MHz. Test results are presented. A description and a status report on the development of a 32/16-channel CCD-based FASTBUS ICA is offered in the last portion of the paper. The unit has features similar to that of the CAMAC unit, but offers much higher channel density, shorter conversion time, hit detecting capability and lower per-channel cost.
Keywords :
CAMAC; Charge coupled devices; Clocks; Costs; Frequency; Image analysis; Image sampling; Independent component analysis; Integrated circuit noise; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4336912
Filename :
4336912