• DocumentCode
    907429
  • Title

    New Method of Proportional Counter Feedback Biasing for Wide-Range Radiation Dose-Rate Monitors

  • Author

    Kopp, M.K. ; Valentine, K.H. ; Guerrant, G.C. ; Manning, F.W.

  • Author_Institution
    Instrumentation and Controls Division Oak Ridge National Laboratory Oak Ridge, Tennessee 37831, USA
  • Volume
    32
  • Issue
    1
  • fYear
    1985
  • Firstpage
    966
  • Lastpage
    968
  • Abstract
    A prototypic wide-range radiation dose-rate monitor for civil defense applications has been developed and tested. The specified dose-rate range (0 to 500 R/h) was displayed on a single readout scale by using feedback-controlled biasing of a proportional counter. This new method is based on controlling the avalanche multiplication factor (gas gain) of the counter by varying its bias voltage in response to its measured output current (i.e., detected dose rate). The counter output current varies between 0 and 1.5 nA in a quasilogarithmic response to dose rates between 0 and 500 R/h. The corresponding values of gas gain and bias voltage range from 1 to 300 and 200 to 1900 V respectively.
  • Keywords
    Current measurement; Feedback; Gain measurement; Instruments; Ionization; Proportional control; Prototypes; Radiation detectors; Testing; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4336977
  • Filename
    4336977