• DocumentCode
    907514
  • Title

    Smith chart for lossy transmission lines

  • Author

    Kretzschmar, J. ; Schoonaert, D.

  • Volume
    57
  • Issue
    9
  • fYear
    1969
  • Firstpage
    1658
  • Lastpage
    1660
  • Abstract
    It is shown that under certain circumstances the magnitude of the voltage reflection coefficient Γ can exceed unity even for a passive load. It is possible to deal with such problems on an extension of the normally used Smith chart. Two numerical examples are given as illustrations of the use of this extended chart.
  • Keywords
    Boundary conditions; Capacitance; Impedance; Power transmission lines; Propagation losses; Reflection; Sufficient conditions; Transmission lines; Voltage;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEEE
  • Publisher
    ieee
  • ISSN
    0018-9219
  • Type

    jour

  • DOI
    10.1109/PROC.1969.7352
  • Filename