DocumentCode :
908163
Title :
A loss minimised sinusoidal PWM inverter
Author :
Boys, J.T. ; Walton, S.J.
Author_Institution :
University of Auckland, Electrical & Electronic Engineering Department, Auckland, New Zealand
Volume :
132
Issue :
5
fYear :
1985
fDate :
9/1/1985 12:00:00 AM
Firstpage :
260
Lastpage :
268
Abstract :
Traditional PWM AC motor drives perform well over a wide speed range and have many positive features associated with their simplicity. However, the waveforms used are significantly less than ideal at high modulation depths and low switching rates, particularly with regard to harmonically induced motor losses. An improved strategy for digitally producing PWM based on conventional triangulation methods is presented. A novel technique for reducing the harmonic losses resulting from sinusoidal PWM waveforms is analysed in depth and realised on a 40 kVA inverter. Tests with this inverter on 7.5 kW and 15 kW motors confirm that the inverter´s performance is significantly enhanced for certain operating conditions, without any significant sacrifice.
Keywords :
AC motors; electric drives; invertors; pulse width modulation; 40 kVA inverter; AC motor drives; harmonic losses; motor losses; sinusoidal PWM inverter;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B
Publisher :
iet
ISSN :
0143-7038
Type :
jour
DOI :
10.1049/ip-b:19850037
Filename :
4643933
Link To Document :
بازگشت