• DocumentCode
    908289
  • Title

    Development of the cerenkov ring imaging detector for the SLD

  • Author

    Ashford, V. ; Bienz, T. ; Bird, F. ; Hallewell, G. ; Leith, D. ; McShurley, D. ; Nuttall, A. ; Ratcliff, B. ; Reif, R. ; Schultz, D. ; Shapiro, S. ; Shimomura, T. ; Toge, N. ; Williams, S. ; Bauer, D. ; Caldwell, D. ; Lu, A. ; Yellin, S. ; Cavalli-Sforza,

  • Author_Institution
    Stanford Linear Accelerator Center, Stanford University, Stanford, California 94306
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    113
  • Lastpage
    121
  • Abstract
    Results of recent beam tests of a physics prototype cerenkov Ring Imaging Detector (CRID) for the SLD are reported. The system includes both liquid (C6F14) and gas (isobutane) radiators and an 80 cm quartz TPC with a gaseous TMAE photocathode and proportional wire readout. Measurements of the quality factor (N0) and cerenkov angles of both radiators at various TMAE concentrations and beam momenta are presented. Other system characteristics, including electron lifetimes, spatial resolution, "photon feedback" and preliminary results from third coordinate charge division readout are discussed.
  • Keywords
    Cathodes; Detectors; Electrons; Physics; Prototypes; Q factor; Spatial resolution; Superluminescent diodes; Testing; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337062
  • Filename
    4337062