DocumentCode :
908300
Title :
The recent operational performance of the CERN omega ring imaging cerenkov detector
Author :
Apsimon, R J ; Flower, P S ; Freeston, K.A. ; Hallewell, G D ; Morris, J A G ; Morris, J V ; Paterson, C N ; Sharp, P H ; Uden, C N ; Davenport, M. ; Eades, J ; Coyle, P.A. ; Mercer, D ; Danaher, S. ; McClatchey, R H ; Thacker, N. ; Thompson, L.F.
Author_Institution :
Rutherford Appleton Laboratory, Chilton, Didcot, Oxon 0X11 0QX United Kingdom
Volume :
33
Issue :
1
fYear :
1986
Firstpage :
122
Lastpage :
131
Abstract :
We discuss the design and construction of the Time Projection chambers (TPCs) of the Omega Ring Imaging Cerenkov Detector (RICH). Details are given of the TPC high voltage system and its monitoring and control. In addition, the operation and monitoring of the readout is described together with results of tests on the performance of the front end amplifiers. The operation of the RICH TPCs and electronics during the first data run of WA69, in 1984, is discussed together with relevant results from laboratory tests. Results from the preliminary analysis of a sample of data from the 1984 run are also presented.
Keywords :
Control systems; Copper; Detectors; Electronic equipment testing; Laboratories; Mesons; Monitoring; Spectroscopy; Voltage control; Wires;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1986.4337063
Filename :
4337063
Link To Document :
بازگشت