• DocumentCode
    908300
  • Title

    The recent operational performance of the CERN omega ring imaging cerenkov detector

  • Author

    Apsimon, R J ; Flower, P S ; Freeston, K.A. ; Hallewell, G D ; Morris, J A G ; Morris, J V ; Paterson, C N ; Sharp, P H ; Uden, C N ; Davenport, M. ; Eades, J ; Coyle, P.A. ; Mercer, D ; Danaher, S. ; McClatchey, R H ; Thacker, N. ; Thompson, L.F.

  • Author_Institution
    Rutherford Appleton Laboratory, Chilton, Didcot, Oxon 0X11 0QX United Kingdom
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    122
  • Lastpage
    131
  • Abstract
    We discuss the design and construction of the Time Projection chambers (TPCs) of the Omega Ring Imaging Cerenkov Detector (RICH). Details are given of the TPC high voltage system and its monitoring and control. In addition, the operation and monitoring of the readout is described together with results of tests on the performance of the front end amplifiers. The operation of the RICH TPCs and electronics during the first data run of WA69, in 1984, is discussed together with relevant results from laboratory tests. Results from the preliminary analysis of a sample of data from the 1984 run are also presented.
  • Keywords
    Control systems; Copper; Detectors; Electronic equipment testing; Laboratories; Mesons; Monitoring; Spectroscopy; Voltage control; Wires;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337063
  • Filename
    4337063