Title :
Adaptive filter for microwave radiometry
Author_Institution :
CSIRO, Division of Applied Physics, National Standards Laboratory, Sydney, Australia
Abstract :
An adaptive filter, which combines the advantages of both short (about 0.5 s) and long (about 2 min) integrating time constants, is described. The recording time constant will be long for a steady level of input signal, but will proportionally shorten when there is a change in the average level of the input signal. If steady conditions continue after a change, the time constant will gradually become long again.
Keywords :
microwave filters; microwave measurement; radiometers;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19700233