A Reliable Automatic Liquid Nitrogen Filling System
Author :
Landis, D.A. ; Madden, N.W. ; Goulding, F.S.
Author_Institution :
Lawrence Berkeley Laboratory University of California Berkeley, California 94720 U.S.A.
Volume :
33
Issue :
1
fYear :
1986
Firstpage :
399
Lastpage :
402
Abstract :
An automatic liquid nitrogen filling system is described. Two of these units have been in use at an unattended location for 10 months without failure. The system automatically refills a 5 liter detector cryostat as required from a 50 liter supply Dewar. The liquid nitrogen filling system is comprised of three basic components: an analog level monitor, a low loss liquid transfer mechanism and a controller. These will be described in the text.
Keywords :
Automatic control; Coaxial components; Computerized monitoring; Control systems; Detectors; Dielectric liquids; Filling; Nitrogen; Oscillators; Probes;