Abstract
In 1983 we, at FERMILAB, began looking at ways to construct a large FASTBUS data manipulation system for the Collider Detector at FERMILAB; a system consisting of about 35 FASTBUS racks each housing up to three FASTBUS crates. Each crate may be required to dissipate Ltp to 2.5 kw of electrical power in the form of heat. This paper describes some of the tests run, the test results, and the final system configuration.
Keywords
Connectors; Cooling; Design engineering; Fastbus; Laboratories; Printed circuits; Switches; System testing; Temperature; Water heating;