DocumentCode :
910340
Title :
MARK II End Cap Calorimeter Electronics
Author :
Jared, R.C. ; Haggerty, J.S. ; Herrup, D.A. ; Kirsten, F.A. ; Lee, K.L. ; Olson, S.R. ; Wood, D.R.
Author_Institution :
Lawrence Berkeley Laboratory Berkeley, CA 94720 U.S.A.
Volume :
33
Issue :
1
fYear :
1986
Firstpage :
916
Lastpage :
921
Abstract :
An end cap calorimeter system has been added to the MARK II detector in preparation for its use at the SLAC Linear Collider. The calorimeter uses 8744 rectangular proportional counter tubes. This paper describes the design features of the data acquisition electronics that has been installed on the calorimeter. The design and use of computer-based test stands for the amplification and signal-shaping components is also covered. A portion of the complete system has been tested in a beam at SLAC. In these initial tests, using only the calibration provided by the test stands, a resolution of 18%/¿E* was achieved.
Keywords :
Calibration; Circuit testing; Coaxial cables; Detectors; Electron tubes; Preamplifiers; Pulse amplifiers; Signal design; Signal resolution; System testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1986.4337248